ENGINEERED FOR
PURITY.
EVERY STAGE MATTERS.
A calibrated ten-stage physical, chemical, and microbiological purification sequence, engineered to maintain uncompromising quality from raw intake to hermetic packaging.
A SYSTEMATIC APPROACH TO
WATER ENGINEERING.
At Herbal Valley Products (Palakkayam) LLP, pure drinking water is not the outcome of a single filter—it is achieved through a calibrated multi-barrier engineering sequence where each stage targets specific physical, dissolved, and microbiological characteristics.
Sourced from monitored open-well catchment aquifers in Palakkayam at the foothills of the Western Ghats, raw intake water is systematically clarified, filtered through granular media, polished via high-pressure reverse osmosis membranes, stabilized in sanitary food-grade buffers, and shielded with dual microbiological disinfection barriers before automated cleanroom bottling.
Graded Multi-Barrier Protection
Coarse sediment removal down to 0.1-micron polishing ensures downstream membranes operate at peak hydraulic efficiency and mineral precision.
Sanitary Stainless-Steel Metallurgy
All intermediate buffer reservoirs, cartridge housings, and distribution manifolds are constructed from hygienic SS304/SS316 food-grade alloys.
Continuous Quality Assurance
Strict batch sampling, in-line conductivity monitoring, and full compliance with Bureau of Indian Standards specification IS 14543.
Engineered for continuous reliability, our closed-loop facility combines high-capacity membrane filtration with hydrostatic telemetry to guarantee pristine water consistency.
THE 10-STAGE PURIFICATION SEQUENCE
A verified, sequential multi-barrier workflow that moves raw water through graded media, molecular membranes, sanitary buffers, and dual disinfection systems.
Sand Filtration
Captures suspended solids, silt & natural catchment turbidity.
Quartz & Silica MediaActivated Carbon
Adsorbs dissolved organic compounds, chlorine & odors.
High-Porosity GAC5-Micron Guard
Traps microscopic particulates to safeguard RO membranes.
5.0µm Depth CartridgeReverse Osmosis
Removes excess dissolved solids & heavy inorganic salts.
TFC Polyamide Membrane5000L Permeate Tank
Accumulates RO permeate and decouples generation from packaging.
5,000L Sanitary SS3040.2/0.1µm Filter
Pleated sub-micron polishing delivers optical crystalline brilliance.
0.2/0.1 Micron Absolute5000L Feed Buffer
Maintains steady hydraulic head pressure for ozonator injection.
5,000L Secondary BufferOzonation Unit
Corona discharge generates active O3 for potent microbicidal oxidation.
Corona Discharge Loop5000L Dwell Tank
Guarantees calibrated hydraulic dwell for complete ozone reaction.
5,000L SS316 Dwell TankUV Treatment
Terminal 254nm photolytic barrier immediately feeding bottling carousels.
254nm In-Line ReactorMEDIA CLARIFICATION & ADSORPTION
Sand Filtration
Intake groundwater from our monitored Palakkayam aquifers enters the primary depth-filtration vessel under controlled hydraulic pressure. Stratified beds of multi-grade quartz sand, silica grains, and graded gravel capture insoluble suspended matter, soil silt, and seasonal catchment turbidity.
| Media Bed | Graded Quartz Sand & Coarse Silica Gravel |
|---|---|
| Removal Target | Suspended Particulates & Natural Turbidity |
| Regeneration | Scheduled Hydrodynamic Backwash Cycle |
Activated Carbon Filtration
Downstream of sand clarification, water passes through high-porosity granular activated carbon (GAC). The expansive internal surface area chemically adsorbs trace volatile organics, chlorine residues, and unwanted odors while refining the natural taste profile and shielding subsequent RO membranes.
| Active Matrix | High-Porosity Granular Activated Carbon (GAC) |
|---|---|
| Adsorption Role | Trace Organics, Chlorine Compounds & Odor |
| Downstream Benefit | Guarantees Membrane Longevity & Crisp Taste |
5-MICRON CARTRIDGE GUARD
5-Micron Cartridge Guard Filtration
Mounted immediately upstream of the high-pressure booster pumps, this stainless-steel housing contains thermally spun polypropylene depth-filter elements rated precisely at 5.0 microns. It intercepts microscopic sand fines and carbon dust that might escape the primary vessels, protecting downstream membranes from abrasive particulate wear.
| Pore Rating | 5.0 Microns (Nominal Mechanical Cut-Off) |
|---|---|
| Housing Metallurgy | Sanitary SS304 Pressure Cylinder |
| Telemetry | Inlet & Outlet Differential Pressure Gauges |
| Downstream Protection | Prevents Spiral-Wound RO Membrane Abrasion |
REVERSE OSMOSIS & BUFFERING
High-Pressure Reverse Osmosis (RO) Skid
Pre-clarified water is pressurized through spiral-wound thin-film composite (TFC) polyamide membranes. Operating across a precision molecular cut-off, the RO system separates dissolved mineral salts, excess inorganic complexes, and heavy ions, discharging a concentrated reject stream while yielding crisp, pure permeate water.
5000L Permeate Storage Tank
Pure RO permeate accumulates in a food-grade stainless-steel reservoir. This dedicated 5000-Litre vessel decouples continuous membrane generation from downstream packaging demand, maintaining steady hydraulic equilibrium.
SUB-MICRON FILTRATION & BUFFER
Fine Sub-Micron Filtration (0.2 / 0.1 Micron)
Drawing water from the initial buffer reservoir, this high-precision polishing barrier utilizes pleated polyethersulfone (PES) membrane cartridges rated down to 0.2 / 0.1 microns. It captures sub-microscopic particulates and cellular fragments, establishing crystalline optical brilliance prior to oxidation treatment.
5000L Secondary Buffer Tank
Polished water enters the second 5000-Litre vertical stainless-steel reservoir. This vessel balances hydraulic inflow from the fine filter array and maintains constant head pressure for the downstream ozonator venturi loop.
| Pore Rating | 0.2 / 0.1 Micron Absolute Verification |
|---|---|
| Cartridge Medium | Hydrophilic Pleated Polyethersulfone (PES) |
| Vessel Geometry | Vertical Cylindrical with Sanitary Dished Ends |
| Hygiene Features | Hydrophobic Sterile Air Vent & CIP Ports |
OZONATION & UV DISINFECTION
Corona Discharge Ozonation & 5000L Dwell
Water is circulated through an industrial corona-discharge ozone generation unit equipped with a high-velocity venturi contact loop. Nascent ozone (O3) dissolves into the flow, acting as a potent physical-chemical oxidizer that inactivates microorganisms without chemical additives.
The water then enters the third 5000-Litre SS316 reservoir, providing calibrated hydraulic dwell time to ensure complete reaction contact before natural decomposition back into pure oxygen.
| Technology | Corona Discharge with Venturi Injector |
|---|---|
| Dwell Tank | 5,000L Sanitary SS316 (Ozone-Resistant) |
| Byproduct | Zero Chemical Residue (Reverts to Pure O2) |
Terminal Ultraviolet (UV) Treatment
Positioned immediately prior to the cleanroom bottling lines, this sanitary stainless-steel reactor subjects water to high-intensity germicidal UV-C radiation at 254 nanometers. High-output quartz lamps disrupt microbial DNA transcription instantly without altering mineral balance, temperature, or taste.
This terminal safeguard delivers pure, validated water directly into the automated cleanroom filling carousel under positive pressure.
| Wavelength | 254 nm Germicidal UV-C Band |
|---|---|
| Reactor Housing | Sanitary Polished SS316L Cylinder |
| Discharge | Direct Hermetic Feed to Cleanroom Bottling |
QUALITY CONTROL ARCHITECTURE
Every stage of our process operates under controlled operational parameters and strict quality protocols. From raw intake to palletized cartons, water quality is verified through scheduled physicochemical and microbiological batch analysis.
Physicochemical Testing
Routine in-line and benchtop verification of Total Dissolved Solids (TDS), pH balance, electrical conductivity, and optical turbidity to maintain consistent mineral composition.
Microbiological Screening
Incubation and membrane filtration testing for coliforms, yeast, and mold to ensure water exiting our ozone and UV train is completely microbially pure.
BIS IS 14543 Compliance
Full compliance with the Bureau of Indian Standards specification IS 14543 for packaged drinking water, supported by certified batch documentation.
In-Line Batch Traceability
Non-contact inkjet coding applies precise production timestamps, batch codes, and best-before dates on every container for full supply-chain transparency.
FROM PURIFICATION
TO PACKAGING.
Following terminal UV treatment, pure water flows directly into pressurized cleanroom bottling enclosures where bottle blowing, ionized air-rinsing, gravimetric filling, and hermetic capping take place in an isolated, hygienic environment.
PET Blow Molding & Ionized Air Rinsing
Preforms are expanded into ergonomic bottles and inverted for high-pressure ionized de-dusting immediately prior to filling carousel entry.
Rotary Sanitary Filling
Gravimetric cleanroom nozzles deliver calibrated liquid volume under laminar airflow without contact between nozzle and container neck.
Hermetic Capping with Tamper-Evident Closure
Torque-calibrated chucks apply 30mm tamper-evident caps immediately after filling, locking in purity and preventing atmospheric ingress.
Precision Labeling & Carton Packaging
High-resolution brand labeling, laser batch coding, and corrugated carton case packing prepare sealed cartons for distribution across Kerala.
PURITY THROUGH EVERY STAGE.
REFRESHMENT IN EVERY BOTTLE.
Discover the manufacturing approach behind Herbal Valley. Experience our two distinct bottled-water brands, produced under the same rigorous ten-stage filtration train at our modern Palakkayam facility.